Differences between revisions 1 and 3 (spanning 2 versions)
Revision 1 as of 12:20:36 23-01-2018
Size: 205
Comment:
Revision 3 as of 14:50:06 23-01-2018
Size: 2961
Comment:
Deletions are marked like this. Additions are marked like this.
Line 4: Line 4:
= WARNING This page is being edited in preparation for a new release =
Line 5: Line 7:
= My sub-section heading 1 =
Line 7: Line 8:
Some text = The EDDY QC tools =
The EDDY QC framework consists of two different tools that automatically perform QC both at the single subject and study-wise level.
 * '''QUAD''' (''QUality Assessment for DMRI'') generates single subject reports and stores the quality assessment indices for each subject.
 * '''SQUAD''' (''Study-wise QUality Assessment for DMRI'') reads all the single subject outputs from QUAD, generates study-wise reports and, optionally, enters these into a database. Moreover, SQUAD can optionally update single subject reports, indicating how the subject’s dataset compares to other data, using either a study-specific group database or a pre-generated database obtained from a different dataset. Lastly, SQUAD also allows to report QC indices based on user-provided variables.

The tools can be called from the command line using `eddy_quad` and `eddy_squad`.


= Running QUAD =
QUAD expects an EDDY output basename to identify the relevant output files that have been generated according to some user-specified options. If a feature, e.g., outliers detection and replacement, was not used, the outliers-related quality metrics will not be included in the final report nor added to the single-subject database.
The most basic way to run `eddy_quad` after having pre-processed the dMRI dataset consists in running the following example command:
{{{
eddy_quad <eddy_output_basename> -idx <eddy_index_file> -par <eddy_acqparams_file> -m <nodif_mask> -b <bvals>
}}}
This will result in the creation of a new folder, called `<eddy_output_basename>.qc`. This will contain the single subject QC report and database, together with the slices included in the report stored as single image files.

== List of input parameters ==
 * Compulsory arguments:
 .[[https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/eddy/UsersGuide#A--out|<eddy_output_basename>]] <<BR>> Basename for EDDY output-files, i.e., corrected images and QC files.
 .[[https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/eddy/UsersGuide#A--index|-idx <eddy_index_file>, --eddyIdx=<eddy_index_file>]] <<BR>> Text file containing indices linking each acquired volume to the acquisition parameters
 .[[https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/eddy/UsersGuide#A--acqp|-par <eddy_acqparams_file>, --eddyParams=<eddy_acqparams_file>]] <<BR>> Text file containing acquisition parameters
 .[[https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/BET|-m <nodif_mask>, --mask=<nodif_mask>]] <<BR>> Binary mask file for the whole brain or a specific region. All voxel-wise QC metrics consider entries only from the marked voxels.
 .[[https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/FDT/UserGuide#DTIFIT|-b <bvals>, --bvals=<bvals>]] <<BR>> b-values text file

 * Optional arguments:

WARNING This page is being edited in preparation for a new release

The EDDY QC tools

The EDDY QC framework consists of two different tools that automatically perform QC both at the single subject and study-wise level.

  • QUAD (QUality Assessment for DMRI) generates single subject reports and stores the quality assessment indices for each subject.

  • SQUAD (Study-wise QUality Assessment for DMRI) reads all the single subject outputs from QUAD, generates study-wise reports and, optionally, enters these into a database. Moreover, SQUAD can optionally update single subject reports, indicating how the subject’s dataset compares to other data, using either a study-specific group database or a pre-generated database obtained from a different dataset. Lastly, SQUAD also allows to report QC indices based on user-provided variables.

The tools can be called from the command line using eddy_quad and eddy_squad.

Running QUAD

QUAD expects an EDDY output basename to identify the relevant output files that have been generated according to some user-specified options. If a feature, e.g., outliers detection and replacement, was not used, the outliers-related quality metrics will not be included in the final report nor added to the single-subject database. The most basic way to run eddy_quad after having pre-processed the dMRI dataset consists in running the following example command:

eddy_quad <eddy_output_basename> -idx <eddy_index_file> -par <eddy_acqparams_file> -m <nodif_mask> -b <bvals>

This will result in the creation of a new folder, called <eddy_output_basename>.qc. This will contain the single subject QC report and database, together with the slices included in the report stored as single image files.

List of input parameters

 