Differences between revisions 3 and 4
Revision 3 as of 14:50:06 23-01-2018
Size: 2961
Comment:
Revision 4 as of 15:07:36 23-01-2018
Size: 3665
Comment:
Deletions are marked like this. Additions are marked like this.
Line 33: Line 33:
 .[[https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/topup/TopupUsersGuide#A--fout|-f <fieldmap>, --field=<fieldmap>]] <<BR>> TOPUP estimated field (in Hz). When provided, QUAD will compute a voxel displacement map.
 .[[https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/FDT/UserGuide#DTIFIT|-g <bvecs>, --bvecs=<bvecs>]] <<BR>> b-vectors text file - use only when storing the EDDY residuals.
 .-o <output folder>, --output-dir=<output folder> <<BR>> Output directory - default = `<eddy_output_basename>.qc`.
 .[[https://fsl.fmrib.ox.ac.uk/fsl/fslwiki/eddy/UsersGuide#A--slspec|-s <slspec>, --slspec=<slspec>]] <<BR>> Text-file describing slice acquisition order.
 .-v, --verbose <<BR>> When set, display debug messages.

WARNING This page is being edited in preparation for a new release

The EDDY QC tools

The EDDY QC framework consists of two different tools that automatically perform QC both at the single subject and study-wise level.

  • QUAD (QUality Assessment for DMRI) generates single subject reports and stores the quality assessment indices for each subject.

  • SQUAD (Study-wise QUality Assessment for DMRI) reads all the single subject outputs from QUAD, generates study-wise reports and, optionally, enters these into a database. Moreover, SQUAD can optionally update single subject reports, indicating how the subject’s dataset compares to other data, using either a study-specific group database or a pre-generated database obtained from a different dataset. Lastly, SQUAD also allows to report QC indices based on user-provided variables.

The tools can be called from the command line using eddy_quad and eddy_squad.

Running QUAD

QUAD expects an EDDY output basename to identify the relevant output files that have been generated according to some user-specified options. If a feature, e.g., outliers detection and replacement, was not used, the outliers-related quality metrics will not be included in the final report nor added to the single-subject database. The most basic way to run eddy_quad after having pre-processed the dMRI dataset consists in running the following example command:

eddy_quad <eddy_output_basename> -idx <eddy_index_file> -par <eddy_acqparams_file> -m <nodif_mask> -b <bvals>

This will result in the creation of a new folder, called <eddy_output_basename>.qc. This will contain the single subject QC report and database, together with the slices included in the report stored as single image files.

List of input parameters

 

eddyqc/UsersGuide (last edited 17:16:00 16-02-2022 by MichielCottaar)